ISOCOM LTD: BSI9000 and CECC20000 Approved Manufacturer

Hutton Close, Crowther Ind Est, Washington, Tyne & Wear NE38 0AH, England
Email: enquiry@isocomoptocouplers.com - Tel: +44 (0)191 4166546 - Fax: +44 (0)191 4155055

Radiation Effects Data

Radiation Hardness Assessment of Isocom Optocouplers by British Aerospace (42K)
Home Page

Isocom products have been independently assessed by British Aerospace, Bristol. A detailed report is available on request.

4N556N1346N140A
Neutron Fluence Hard To> 3E12 n/cm2> 1E13 n/cm2> 3E12 n/cm2
Total Dose Hard To1 Mrad (Si)1 Mrad (Si)30 krad @ If=0.5mA
0.1 Mrad @ If=1.5mA
1 Mrad @ If=5mA
Dose Rate Hard To6E9 rad (Si)/sec
Vcc photocurrent up to1.6 A1.5 A5.2 A
Output transient upset up to5 µs15 µs9 µs