IS814, IS824, IS844
AC Input Type Photocoupler

Circuit
Features
Absolute Maximum Ratings
Electrical Characteristics

Similar Optocouplers
Home Page


Circuit

OPTOCOUPLER CIRCUIT
IS814
IS824
IS844

Features

AC or Polarity Insensitive Input
Current Transfer Ratio Min 20% @ If= ±1 mA, Vce = 5 V
High Isolation Voltage between Input and Output: Viso = 5000 Vrms
Compact Dual-In-Line Package
UL Recognised
Surface Mount Option Available

Applications

Programmable Controllers, Telephone Sets, Telephone Exchangers, Systems Appliances, Signal Transmission between Circuits of Different Potentials and Impedances.

Absolute Maximum Ratings (Ta=25°C)

Storage Temperature:
Operating Temperature:
Lead Soldering Temperature:
Isolation Voltage:
-55°C to +125°C
-30°C to +100°C
260°C (for 10s)
5000 Vrms (RH=40~60%, AC for 1 minute)

Input Diode

Forward Current:
Forward Current Peak:
Power Dissipation:
±50mA
±1A (Pulse Width <=100µs, Duty Ratio=0.001)
70mW

Output Transistor

Collector-Emitter Voltage:
Emitter-Collector Voltage:
Collector Current:
Collector Power Dissipation:
35V
6V
50mA
150mW

Package

Total Power Dissipation: 200mW

Electro-optical Characteristics (Ta=25°C)

INPUT PARAMETER CONDITIONS MIN TYP MAX UNIT
VF Forward Voltage IF=±20mA
1.2 1.4 V
VFM Peak Forward Voltage IFM=±0.5A

3.0 V
CT Terminal Capacitance V=0, f=1kHz
30 250 pF
OUTPUT PARAMETER CONDITIONS MIN TYP MAX UNIT
ICEO Collector Dark Current VCE=20V, IF=0

100 nA
TRANSFER
CTR Current Transfer Ratio VCE=5V, IF=±1mA 20
300 %
VCE(SAT) Collector-Emitter Saturation Voltage IF=±20mA, IC=1mA
0.1 0.2 V
RISO Isolation Resistance 500Vdc, RH=40~60% 50 100
Gohm
CF Floating Capacitance V=0, f=1MHz
0.6 1.0 pF
FC Cut-Off Frequency VCE=5V, IC=2mA, RL=100ohm 15 80
kHz
TR Response Time (Rise) VCE=2V, IC=2mA, RL=100ohm
4 18 µs
TF Response Time (Fall) 3 µs