Hutton Close, Crowther Ind Est, Washington, Tyne & Wear NE38 0AH, England
Email: enquiry@isocomoptocouplers.com
- Tel: +44 (0)191 4166546 - Fax: +44 (0)191 4155055
Circuit
Features
Description
Absolute Maximum Ratings
Insulation
Rated Parameters
Isolation Characteristics
Similar Optocouplers
Home
Page
Rated Impulse Voltage (Transient Overvoltage): VIOTM=6 kVpeak
Insulation Test Voltage (Partial Discharge Test): VPD=1.4
kVpeak
Rated Insulation Voltage (RMS includes d.c.): VIOWM=600 VRMS
(848 Vpeak)
Rated Recurring Peak Voltage (repetitive): VIORM=600 VRMS
Isolation Materials: According to UL 94
Creeping Current Resistance: According to VDE 0303 Part 1/06.84 (IEC 112)
Climatic Classification: 55/100/21 (IEC 68 Part 1)
Comparative Tracking Index: CTI 275 (VDE 0109/12.83*)
Pollution Degree: 2 (VDE 0109/12.83*)
(*Identical with VDE 0110 Part 1/01.89)
The H11 AV series are optically coupled isolators consisting of a Gallium
Arsenide infrared emitting diode and an NPN silicon phototransistor mounted in a
standard 6-pin dial-in-line package. Surface Mount Option Available.
The product type number consists of the basic product type followed by the
letter "X" which indicates VDE 0884 approval of the basic part. Letter
"X" supercedes letter "V" which denoted the now obsolete VDE
0883 approval.
For 10mm lead spread requirement add suffix G.
For surface mount requirements add suffix SM.
These couplers meet the requirements of the following Equipment Standards:
VDE 0109/12.83, VDE 0110/01.89:
Circuits for safe protective
separation against electrical shock according to safety class II (reinforced
isolation).
Application class I-IV at mains voltages <= 300V.
Application class I-III at mains voltages <= 600V.
VDE 0804/05.89:
Telecommunication Apparatus and Data Processing
VDE 0805/05.90 (IEC 950):
Data Processing Equipment and Office
Machines (Option G only).
VDE 0860/05.89 (IEC 65):
Safety for mains-operated electronic
and related apparatus for household.
UL 1577/09.89:
Standard for Safety Optical isolated switch
systems. Package type K.
BS 415/1990; IEC 65/1985:
Safety requirements for
mains-operated electronic and related apparatus for household and similar
general use. Class II applications.
EN 60950/1989:
Specification for safety of information
technology equipment including electrical business equipment (Option G only).
Absolute Maximum Ratings (Ta=25°C) | |
| Storage Temperatare: Operating Temperature: Lead Soldering: Input-to-Output Insulation Test Voltage: |
-55°C to +125°C -55°C to +125°C 260°C for 10s, 2mm from case 6kVpeak (Transient Overvoltage, t=10s) |
Output Transistor | |
| Collector-emitter Voltage BVceo: Emitter-base Voltage BVebo: Collector-base Voltage BVcbo: Collector Current: Collector Current: Power Dissipation: Derate Linearly: |
70V 7V 70V 50mA 100mA (tp <= 10ms, Duty Ratio 0.5) 150mW 2.00mW/°C above 25°C |
Input Diode | |
| Forward DC Current: Reverse DC Voltage: Peak Forward Current: Power Dissipation: Derate Linearly: |
60mA 6V 3A (1µs p.w. 300pps) 100mW 1.33mW/°C above 25°C |
Package | |
| Total Power Dissipation: Derate Linearly: |
250mW 3.3mW/°C above 25°C |
0884 VDE Maximum Safety Ratings | |
| Input Diode Isi: Output Transistor Psi: Coupled Device Inpulse Voltage Viotm: Safety Temperature Tsi: |
130mA max 265mW max 6kV MAX 200°C |
This device is suitable for safe electrical isolation only within the maximum safety ratings. This must be ensured by protective circuits in the applications.
This device is suitable for safe electrical isolation only within the maximum safety ratings. This must be ensured by protective circuis in the applictions
| PARAMETER | TEST CONDITIONS | MIN | MAX | UNIT |
|---|---|---|---|---|
| LOT SAMPLE TESTING | ||||
| Transient Overvoltage Rating (VIOTM) | Fig 1. VIOTM=6kVpeak, TINI=10s | No breakdown may occur | ||
| Partial Discharge Measurement | Fig 1. VPD=1.05kVpeak TP=60s | 5 | pC | |
| Insulation Resistance | VIO=500Vdc, TAMB=25°C | 1E12 | Ohm | |
| VIO=500Vdc, TAMB=100°C | 1E11 | Ohm | ||
| VIO=500Vdc, TSI=200°C (construction test only) | 1E9 | Ohm | ||
| 100% ROUTINE TESTING | ||||
| Partial Discharge Measurement | Fig 2. VPD=1.4kVpeak, TP=1s | 5 | pC | |
| INPUT | PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT |
|---|---|---|---|---|---|---|
| VF | Forward Voltage | IF=10mA | 0.8 | 1.5 | V | |
| IF=10mA, TA=-55°C | 0.9 | 1.7 | V | |||
| IF=10mA, TA=+100°C | 0.7 | 1.4 | V | |||
| IR | Reverse Current | VR=6.0V | 10 | µA | ||
| Capacitance | VR=0, f=1MHz | 30 | pF | |||
| OUTPUT | ||||||
| BVCEO | Collector-emitter Voltage | IC=1mA | 70 | V | ||
| BVEBO | Emitter-base Voltage | IE=0.1mA | 7 | V | ||
| BVCBO | Collector-base Voltage | IC=0.1mA | 70 | V | ||
| ICEO | Collector-emitter Dark Current | VCE=10V, IF=0 | 50 | nA | ||
| CCE | Collector-emitter Capacitance | VCE=10V, f=1MHz | 2 | pF | ||
| COUPLED | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
| IC/IF | DC Current Transfer Ratio | IF=10mA, VCE=10V | ||||
| H11AV1X | 100 | 300 | % | |||
| H11AV2X | 50 | % | ||||
| H11AV3X | 20 | % | ||||
| RIO | Input-to-Output Isolation Resistance | VIO=500V, (Note 1) | 1000 | Gohm | ||
| VCE(SAT) | Collector-emitter Saturation Voltage | IF=20mA, IC=2.0mA | 0.4 | V | ||
| CIO | Capacitance Input to Output | f=1MHz, (Note 1) | 0.5 | pF | ||
| tON | Turn-on Time | VCC=10V, IC=2mA | 15 | µs | ||
| tOFF | Turn-off Time | RL=100ohm | 15 | µs | ||
1. Measured with input leads shorted together and output leads shorted together
| DESCRIPTION | SYMBOL | CHARACTERISTIC |
|---|---|---|
| Installation Category (DIN VDE0109, Dec 1983, Table 1) | I-IV I-III | |
| IEC Climatic Category (DIN IEC 68 Part 1/09.80) | 55/150/21 | |
| Pollution Degree (DIN VDE0109, Dec 1983) | 2 | |
| Maximum Operating Isolation Voltage | VIORM | 630 V |
| Test Voltage Input/Output, Procedure B(1) VPR=1.6 x VIORM, Sample Test with tP=1s, Partial Discharge<5pC |
VPR | 1000 V |
| Test Voltage Input/Output, Procedure A(1) VPR=1.2 x VIORM, Type and Sampling Test with tP=60s, Partial Discharge<5pC |
VPR | 720 V |
| Maximum Permissable Overvoltage Transient Overvoltage, tTR=10s, Procedure A(1) |
VTR | 6000 V |
| Isolation Resistance, TSI VI/O=500V | RIS | >=1 Gohm |
| Safety Maximum Ratings (max permissible ratings in case of a fault): | ||
| Package Temperature | TSI | 175 °C |
| Current (IF, PSI=0) | ISI | 400 mA |
| Power (Output or Total Power Dissipation) | PSI | 700 mW |
Isocom takes great effort to ensure accurate data, but regrettably cannot be held liable for any error on its website. Visit File Lists to confirm old printouts are up-to-date.