Hutton Close, Crowther Ind Est, Washington, Tyne & Wear NE38 0AH, England
Email: enquiry@isocomoptocouplers.com
- Tel: +44 (0)191 4166546 - Fax: +44 (0)191 4155055
Circuit
and Package
Features
Description
Absolute Maximum Ratings
Recommended
Operating Conditions
Electrical Characteristics
Reliability and Approvals
Similar
Optocouplers
Home Page
![]() |
2 - Anode 3 - Cathode |
5 - GND 6 - Vo 7 - BASE (CS810/811 NOT CONNECTED) 8 - Vcc |
Hermetically sealed 8 pin ceramic dual in line package
High speed; Typ.
700 kbit/s (NRZ)
1500 Vdc withstand test voltage
High radiation immunity
Performance guaranteed over -55°C to +125°C
ambient temperature range
4N55 function compatible
CS801/811, 15% <= CTR <= 22% at 25°C
CS810/811, base not
connected for improved noise immunity
The CS800 series are single channel devices hermetically sealed in 8 pin
ceramic packages.
They incorporate a GaAsP LED emitter and integrated photon detector.
CS800/810 High speed, TTL compatible optocouplers.
CS801/811 High speed, TTL compatible optocouplers for use in applications
requiring matched or known CTR. At 16mA: 15% <= CTR <= 22%
The CS810 and CS811 are provided with the output transistor base not
connected for greater immunity to noise and reduced ESD susceptibility.
Parts designated /L2 are subject to 100% high reliability screening. Surface Mount Option Available.
Absolute Maximum RatingsInput Diode | |
| Peak forward current: Average forward current: Reverse voltage: Power Dissipation: Storage temperature: Operating temperature: Solder temperature: |
40mA ( <=1ms duration) 20mA 3V 36mW -65°C to +150°C -55°C to +125°C 260°C for 10s |
Output Detector | |
| Supply voltage VCC: Average current IO: Peak current IO: Voltage VO: Emitter-base rev. voltage BVEBO: Base current IB: Collector power dissipation: |
-0.5V to 20V 8mA 16mA -0.5Vto 20V 3V 5mA 50mW |
| PARAMETER | SYMBOL | MIN | MAX | UNIT |
| Input Current, Low level | IEL | 250 | µA | |
| Input Current, High level | IEL | 16 | 20 | mA |
| Supply Voltage | VCC | 2 | 18 | V |
(Ta=-55° to +125°C u.o.s.) *All Typical values at Vcc= 5V Ta=25°C
| PARAMETER | SYMBOL | DEVICE | CONDITIONS | MIN | TYP* | MAX | UNIT |
| Current transfer ratio | hf(CTR) | CS800/810 | VCC=4.5V, VO=0.4V, IF=16mA, TA=25°C | 17 | % | ||
| CS801/811 | 15 | 22 | % | ||||
| CS800/810 | IF=16mA, VO=0.4V, VCC=4.5V | 9 | % | ||||
| CS801/811 | 9 | % | |||||
| Logic low output voltage | VOL | VCC=4.5V, IF=16mA, IO=1.44mA | 0.3 | 0.4 | V | ||
| Logic high output current | IOH | IF=0, VO=VCC=18V | 0.05 | 100 | µA | ||
| Logic high supply current | ICCH | IF=0, VO=OPEN, VCC=18V | 0.05 | 10 | µA | ||
| Logic low supply current | ICCL | VCC=18V, IF=20mA | 30 | 200 | µA | ||
| Input forward voltage | VF | IF=20mA | 1.45 | 1.9 | V | ||
| Input reverse breakdown | VBR | IR=10µA | 3 | V | |||
| I/O insulation leakage current | IIO | RH=45%, TA=25°C, |
1.0 | µA | |||
| Propagation delay to logic low o/p | tPHL | RL=8.2kohm, IF=16mA, VCC=5V | 0.5 | 2.0 | µs | ||
| Propagation delay to logic high o/p | tPLH | 1.2 | 6.0 | µs |
Isocom Ltd supplies high reliability devices for applications requiring an
operating temperature range of -55°C to +125°C (e.g. military
applications).
Devices supplied have completed rigorous testing, and various
high reliability test options are offered.
As manufacturer of high reliability optocouplers Isocom Ltd's manufacturing
plant at North East England, has site approval to BS9000 (registered number
1294/M) and CECC20000 (registered number M/1084/CECC/UK) issued by the British
Standards Institution.
Together with CECC, BS9000 is a preferred standard for use in European
military projects. Consequently, Isocom Ltd's approved devices are listed in the
CECC "MUAHAG" preferred products list.
The BS9000 approval is also recognised as meeting the equivalent criteria
to those required by BS5750/ISO9000/EN29000.
The Company's customers can be assured of our commitment to stringent
quality, reliability and inspection standards, as demonstrated by our existing
approvals. Other customer specific options can also be offered.
Isocom takes great effort to ensure accurate data, but regrettably cannot be held liable for any error on its website. Visit File Lists to confirm old printouts are up-to-date.