ISOCOM LTD: BSI9000 and CECC20000 Approved Manufacturer

Hutton Close, Crowther Ind Est, Washington, Tyne & Wear NE38 0AH, England
Email: enquiry@isocomoptocouplers.com - Tel: +44 (0)191 4166546 - Fax: +44 (0)191 4155055

CD650
Dual Channel High Speed Hermetically Sealed Ceramic Optocoupler

Circuit and Package
Features
Description
Absolute Maximum Ratings
Recommended Operating Conditions
Truth Table
Electrical Characteristics
Reliability and Approvals

Similar Optocouplers
Home Page


Circuit and Package

1. Anode Channel 1 Input
2. Cathode Channel 1 Input
3. Cathode Channel 2 Input
4. Anode Channel 2 Input
5. Ground
6. Channel 2 Output Vo2
7. Channel 1 Output Vo1
8. Supply Voltage Vcc

Features

Hermetically Sealed 8-Pin Ceramic Dual-in-Line Package
High Speed: Typically 10 Mbits/s (75 ns max)
TTL Compatable Input and Output
High Common Mode Rejection
Performance Guaranteed Over -55°C to +125°C Ambient Temperature Range
1500 Vdc Withstand Test Voltage

Description

The CD650 is a dual channel device hermetically sealed in an 8-pin ceramic package. It incorporates GaAsP LED emitters and high gain integrated photodetectors. The outputs are open collector Schottky clamped transistors. Surface Mount Option Available.

Applications

Military, high reliability system, telephone ring detection, microprocessor system interface, level shifting, digital logic ground isolation, current loop receiver, isolation input line receiver, system test equipment isolation, process control input/output isolation

Absolute Maximum Ratings

Storage Temperature:
Operating Temperature:
Lead Soldering:
-65°C to +150°C
-55°C to +125°C
260°C for 10s, 1.6mm from case

Input Diode

Peak Forward Current IF:
Average Forward Current IF:
Reverse Voltage VR:
Power Dissipation:
40mA (duration<=1ms, 500pps)
20mA
5V
35mW

Output Detector

Supply Voltage VCC:
Current IO:
Voltage VO:
Collector Power Dissipation:
7V (1 minute max)
25mA
7V
40mW

Total Package

Power Dissipation: 350mW

Recommended Operating Conditions

PARAMETER SYMBOL MIN MAX UNIT
Input Current, Low Level IFL 0 250 µA
Input Current, High Level IFH 6.3 (*) 20 mA
Supply Voltage VCC 4.5 5.5 V
Fan Out (TTL Load) N - 8

* 6.3mA condition permits at least 20% CTR degradation guardband on initial switching threshold of 10mA or less.

Truth Table

INPUT OUTPUT
High Low
Low High

Electrical Characteristics

(Over recommended temperature Ta= -55°C to +125°C u.o.s.; all typical values at Vcc=5V, Ta=25°C each channel.)

SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNIT
IOH High Level Output Current VCC=VO=5.5V, IF=250µA
20 250 µA
VOL Low Level Output Voltage VCC=5.5V, IF=5mA, IOL=13mA
0.4 0.6 V
ICCH High Level Supply Current VCC=5.5V, IF=0
15 30 mA
ICCL Low Level Supply Current VCC=5.5V, IF1,2=10mA
30 38 mA
II-O Input-Output Insulation Leakage Current RH=45%, TA=25°C, t=5s, VIO=1500Vdc

1.0 µA
VF Input Forward Voltage IF=10mA, TA=25°C
1.5 1.75 V
IF=10mA
1.85 V
VBR Input Reverse Breakdown Voltage IR=10µA, TA=25°C 5
V
tPLH Propagation Delay Time to Logic High Output RL=350ohm, CL=15pF, IF=7.5mA, TA=25°C

75 ns
tPHL Propagation Delay Time to Logic Low Output ns
CTR Current Transfer Ratio VO=0.6V, IF=5mA, VCC=5.5V
300
%

Reliability and Approvals

Isocom Ltd supplies high reliability devices for applications requiring an operating temperature range of -55°C to +125°C (e.g. military applications).
Devices supplied have completed rigorous testing, and various high reliability test options are offered. The Company is developing a suitable specification to permit release to CECC 20000.
As a manufacturer of high reliability optocouplers Isocom Ltd's manufacturing plant in North East England, has site approval to BS9000 (registered number 1294/M) issued by the British Standards Institution. Together with CECC, BS9000 is a preferred standard for use in European military projects. Consequently, Isocom Ltd's approved devices are listed in the CECC "MUAHAG" preferred products list.
The BS9000 approval is also recognised as meeting the equivalent criteria to those required by BS5750/ISO9000/EN29000.
The Company's customers can be assured of our commitment to stringent quality, reliability and inspection standards, as demonstrated by our existing approvals. Other customer-specific options can also be offered.

Isocom takes great effort to ensure accurate data, but regrettably cannot be held liable for any error on its website. Visit File Lists to confirm old printouts are up-to-date.