ISOCOM LTD: BSI9000 and CECC20000 Approved Manufacturer

Hutton Close, Crowther Ind Est, Washington, Tyne & Wear NE38 0AH, England
Email: enquiry@isocomoptocouplers.com - Tel: +44 (0)191 4166546 - Fax: +44 (0)191 4155055

PHOTOMOS RELAYS

ISV251-259
ISW214/414/614

Similar Optocouplers: 1 2 3

Optocouplers Catalogue
Home Page


ISV251-259

General Type Photo Mos Relays with standard I/O isolation type and reinforced isolation type. The relays can be normally closed and surface mounted by forming the leads.

Part: ISV 251 252 255 257 253 254 259 258 253H 254H 257H
OUTPUT
Load Volt 40 60 100 200 250 400 1000 1500 250 400 200
Continued Load Current 0.5 0.4 0.35 0.25 0.2 0.15 0.03 0.02 0.2 0.15 0.25
Peak Load Current A 1.8 1.5 1.0 0.75 0.6 0.5 0.09 0.06 0.6 0.5 -
Power Dis mW 360
On Resist MAX Ohm 1.0 1.4 2.5 4.0 8.0 16.0 200 500 8.0 16.0 4.0
Output Cap pF 350 350 350 170 170 170 80 80 170 170 170
Off-State Leakage Current
µA
1 10 10 1 1 1
INPUT
LED If mA 50
Rev Voltage V 3
Peak If A 1
Power Dis mW 75
LED Oper. Current [LED
Oper. (Off) Current]
MAX
3.0 3.0 3 3 3 3 3 3 3.0 3.0 2.0
LED turn off Current
[Rev (ON) current]
MIN
0.4 0.2
LED dropout voltage MAX
If = 5 mA
1.5
Turn-On time [Operate
(OFF) Time]
MAX ms
3.0 3.0 2 3 2.0 2.0 1.0 1 4 3.0 1.0
SWITCHING SPEED
Turn Off time
[Reverse (ON) time]
ms
0.2 0.6
Part: ISV 251 252 255 257 253 254 259 258 253H 254H 257H

Contents

ISW214/414/614

General Type Photo Mos Relays with standard I/O isolation type and reinforced isolation type. The relays can be normally closed and surface mounted by forming the leads.

Part ISW214 ISW414 ISW614
OUTPUT
Load Volt V 400
Continued Load Current A 0.1
Peak Load Current A 0.3
Power Dis mW 800
On Resist MAX Ohm 50
Output Cap pF 45 100 45 (NO) 100 (NC)
Off-State Leakage Current µA 1
INPUT
LED If mA 50
Rev Voltage V 3
Peak If A 1
Power Dis mW 75
LED Operate Current [LED
Oper. (Off) Current]
MAX
3
LED turn off Current
[Rev (ON) current]
MIN
0.4
LED dropout voltage MAX, If = 5 mA 1.5
Turn-On time [Operate (OFF) Time] MAX ms 0.5 1
SWITCHING SPEED
Turn Off time [Reverse (ON) time] ms 0.2 1
Part ISW214 ISW414 ISW614

Contents